| 1. |
Line & Load Regulation, Ripple & Noise and Efficiency : |
| |
Line & Load Regulation |
: |
Limit : 0.1 % CV |
| |
Ripple & Noise |
: |
Limit : 150mV P-P (pard)
(With shortest probe length and 0.1uF/63V parallel with 100uF electrolytic capacitor across the probe tip). |
| |
Efficiency |
: |
80%
Line, Load Regulation and Ripple measured on O/P Busbar. |
| 2. |
I adj |
: |
0 -7.5A adjust by rotary encoder on front panel.
Actual : |
| 3. |
V adj |
: |
0 -100V adjust by rotary encoder on front panel
Actual : |
| 4. |
Over voltage |
: |
Over voltage adjust by rotary encoder on front panel .Factory set : |
| 5. |
Voltage & Current Prog.
By External Pot.
|
: |
For Voltage : 5K =
For Current : 5K = |
| 6. |
O/P V & I proportional O/p |
: |
For Voltage : 100V =
For Current : 7.5A = |
| 7. |
Remote Sense |
: |
Provided with 10V cable drop. |
| 8. |
Transient Recovery Time |
: |
(With local sense) 10mSec from 10% to 90% load change within 2% of set value. |
| 9. |
Indications |
: |
CV : Green LED
CC : Orange LED
Fault : Red LED
O/P ON/OFF : Red / Green (Duel colour LED)
Tx : Orange LED
Rx : Green LED
Remote/Local : Red / Green (Duel colour LED)
4 digit LCD display provided for function and monitor. |
| 10. |
Terminations |
|
Input on 3 pin MS Shell connector.
Output on busbar.
+S & -S on Phoenix connector.
D’ connector for V & R programming, V & I monitor,
Remote ON/OFF. |
| 11. |
Insulation (Factory test) |
: |
A. Between input & chassis : 1000V AC
B. Between input & chassis : 1KV AC
C. Between output & chassis : 500V DC |
| 12. |
Dimensions |
: |
19” * 1U * 430mm (D, excluding projections) |
| 13. |
Colour |
: |