Home About us Request Quote Products News Application Storage Careers Site Map Contact us

 

 


Akiwa




 

Sunix 

 

SPECTRON :-

SOLID STATE SINE WAVE FREQUENCE CONVERTERS
&
CONSTANT VOLTAGE CONSTANT FREQUENCEY (CVCF) SYSTEMS


SPECIFICATIONS
:

Input Voltage for Frequency 110/230/415 Volts, 50/60/40Hz (or any other),

Converters :

 

single or three phase A.C. as per requirement or specifications.

Input Voltage Tolerance :

 

±10% of nominal input voltage. (wider tolerance if possible on request.)

Output Power(at unity P.F) :  

 

100,250,500 & 750VA and 1, 1.5, 2, 3, 4 & 5 KVA In single phase output. 100, 250,500 & 750VA1, 1.5, 2, 3, 4,5,7,5, 10 in three phase output.

Output Voltage :

 

115 Volts single phase or line to neutral in case of three phase (standard). Any other voltage on request. (Typical 36V, 220V single or three phase)

Output voltage settability :

 

±5V standard, ±10V optional at extra cost.

Output Regulation    a) Line :

 

better than ±2%, against input voltage variation of ±10% of nominal input.

                                 b) Load :

 

better than ±2%, against load current variation from no load to full load.

Output Amplitude Stability :

 

better than ±2%, against time (8 hrs.) and temperature (50°C change)

Load power factor :

 

0.8 lagging to unity (Derate power capacity proportionately for load of other than unity power factor Derating to 70% at 0.8PF)

Output Frequency :

 

any frequency from 40Hz to 1,000 Hz (fixed or variable).

Output Frequency stability :

 

better than ±1% against input voltage or load current variation. (better than ±0.05% for crystal controlled models at option for selected frequencies at extra cost).

Wave from Distortion :

 

less than 3% for load variation from no load to full load (resistive) and permissible line voltage variation.

RF Interference (Conducted & Radiated) :

 

NIL

Peak Efficiency (Inversion) :

 

better than 60% at full load and minimum input voltage.

Overall Conversion Efficiency :

 

Around 50%

Protection for Output :

 

Fast acting solid state protection for overload and continuous short-circuit to protect internal circuitry and delayed electromagnetic trip, over and above solid state protection to protect load against over temperature, UV, OV (optional) By mcb/fuse for Frequency Converter.

For Input :

 

against under voltage & over Voltage (optional)
Input present, Output present, OL Trip (standard)

Metering :

 

Analogue for digital meters for monitoring input voltage, output voltage and load current & digital frequency meter for output frequency can be provided at extra cost.

Annunciation :

 
Can be provided on request at extra cost & if feasible.

Environment :

 
-0°C to 55°C, upto 95% RH non-condensing.