Specifications for A0750-13 (100V/7.5A)
Programmable Power Supply (RS232/485

 

  • Front view
 

 

  • Rare view
 

 

Input : 180V to 264VAC, 50Hz, 1 Phase
Output  As per customer`s requirement



1.
Line  & Load Regulation : Limit    : 0.1 % CV  when measured on O/P Busbar/terminal block/studs.
2.
Ripple & Noise :

Limit    : 150mV P-P (pard)
(With shortest probe length and 0.1uF/63V parallel with 100uF electrolytic capacitor across the probe tip).

3.
Efficiency : 80% when measured at nominal input and full load.
4. I adj :

Zero to full scale as per specification. adjust by rotary encoder on front panel.

5. V adj :

Zero to full scale as per specification. adjust by rotary encoder on front panel       

6. Over voltage :

Over voltage adjust by rotary encoder on front panel .Factory set at above 110% of maximum output voltage.

7. Voltage & Current Prog.
By External Pot.

: For Voltage : 5K =  Full scale
For Current : 5K = Full scale
8. O/P V & I proportional O/p :

For Voltage : 10V = Full scale
For Current : 10V = Full scale

9. Remote Sense : Provided.
10. Transient Recovery Time :

(With local sense)  10mSec from 10% to 90% load change within 2% of set value.

11. Indications :

CV  : Green LED
CC  : Orange LED
Fault : Red LED                 
O/P ON/OFF : Red / Green (Duel colour LED)
Tx : Orange LED
Rx : Green LED
Remote/Local : Red / Green (Duel colour LED)
4 digit LCD display provided for function and monitor.

12. Terminations : Input on 3 pin MS Shell connector.